Description

Spirax Sarco BSA and BSAT bellows-sealed globe valves feature a double bellows seal and are designed for steam, gases, liquids, condensate, and water systems. The standard BSAT series is equipped with a throttling plug and stem locking device, while the optional BSA series features a flat plug. These products comply with the European Pressure Equipment Directive 97/23/EC, and EN 10204 3.1 certificates are available for selected models.

Approximate Product Weight (kg)

SizeBSA2 BSA2TBSA3 (DIN)BSA3 (ANSI) ANSI 150BSA3 ANSI 300 JIS/KS 20KBSA6T PN40
DN1544564
DN2045675
DN2556896
DN3278--8
DN401011101111
DN501214121514
DN651619--19
DN802126252926
DN1003644414944
DN1255264---
DN1507588-94-
DN200145---193

Leakage Class

Plug-to-seat sealing complies with EN 12266 - 1 Class A and ISO 5208 Class A. The leakage class for BSA3 (ANSI) complies with API 598 zero-leakage requirements.

Materials

  • BSA6T Materials
No.ComponentBSA6T
1BodyStainless steel EN 10213 1.4408 or STM A351 CF8M
2BonnetStainless steel EN 10213 1.4581
3SeatStainless steel EN 10213 1.4408 or STM A351 CF8M
4DiscDN15 - DN40: stainless steel EN 10088 1.4571; DN50 - DN100: stainless steel EN 100222 1.4571
5BellowsStainless steel DIN 17440 1.4571
6StemStainless steel EN 10088 1.4571
7HandwheelPressed steel BS 1449 CR4
8Stem PackingGraphite
9Bonnet BoltsStainless steel A4 - 70
10Bonnet NutsStainless steel A4
11Body/Bonnet GasketStainless steel-reinforced exfoliated graphite
12Locking NutDN15 - DN80: steel M8×14mm A2 - 70; DN100 - DN150: steel M8×20mm A2 - 70; DN200 - DN250: steel M12×20mm A2 - 70

Stroke Limitation for Throttling Models

The handwheel nuts on BSA2T and BSA3T protective caps have a threaded hole for installing a stroke limiter. Customers must provide the standard bolts and nuts listed in the table below.

SizeHexagon Bolt
DN15 - DN80M8×50mm
DN100 - DN150M12×75mm
DN200 - DN250M12×100mm

The BSA6T handwheel nut also has a threaded hole for installing a stroke limiter. The standard bolts and nuts supplied by the customer are the same as those listed above.

Body Design Conditions

  • BSA2T and BSA2
Body Design ConditionsPN16PN25
PMA - Maximum Allowable Pressure16 bar g25 bar g
TMA - Maximum Allowable Temperature350 °C350 °C
PMO - Maximum Operating Pressure with Saturated Steam14.7 bar g22.3 bar g
TMO - Maximum Operating Temperature (Soft Seat)230 °C230 °C
TMO - Maximum Operating Temperature (Metal Seat)350 °C350 °C
Minimum Operating Temperature-10 °C-10 °C
Maximum Designed Cold Hydraulic Test Pressure24 bar g38 bar g