Description

Spirax Sarco CSF16/CSF16T stainless steel sterile air filters are high-efficiency, in-line filters for horizontal installation, designed to remove particulate contaminants from gas systems. The filter housing is available in several configurations: CSF16 uses austenitic stainless steel 1.4301, while CSF16T uses 1.4404.

The external surfaces of DN8 - DN80 housings are polished, while the internal surfaces have a natural finish. DN100 - DN200 housings have a natural finish on both external and internal surfaces.

The housing consists of two halves and complies with the DIN 11851 food industry connection standard. For DN100 - DN200, the two halves are connected with bolts and nuts. The filter is fitted with a replaceable 0.01μm borosilicate filter element offering a filtration efficiency of more than 99.9998%. Low-flow L-type and high-flow H-type filter elements are available for selected pipe sizes. The product complies with the European Pressure Equipment Directive 97/23/EC. Stamping can be supplied on request. All materials comply with US FDA requirements. EN 10204 3.1 certification is available when specified at the time of ordering.

Sizes and Pipe Connections

  • Threaded connections: BSP/NPT: ¼”, ½”, ¾”, 1”, 1¼”, 1½”, 2”, 2½” and 3”.

  • Flanged connections:

EN 1092 PN16: DN8, DN10, DN15, DN20, DN25, DN32, DN40, DN50, DN65 and DN80.

  • EN 1092 PN10: DN100, DN150 and DN200.

  • ASME 150: ¼”, 3/8”, ½”, ¾”, 1”, 1¼”, 1½”, 2”, 2½”, 3”, 4”, 6” and 8”.

Pressure/Temperature Limits

Body design ratingPN16
Maximum allowable pressure PMADN8 - DN65 (1/4” - 21/2”): 16 bar g; L-type DN80 (3”): 16 bar g; H-type: 12 bar g; DN100 - DN200: 10 bar g
Maximum allowable temperature TMADN8 - DN80: 178°C@8.5barg; DN100 - DN200: 150°C@8.1 bar g
Minimum allowable temperature-20°C
Maximum operating pressure PMODN8 - DN80: 8.5 bar g@178°C; DN100 - DN200: 8.1 bar g @150°C
Maximum operating temperature TMODN8 - DN80: 178°C@8.5 bar g; DN100 - DN200: 150°C@8.1 bar g
Minimum operating temperature0°C
Maximum allowable differential pressure ΔPMX5 bar g
Maximum design cold hydraulic test pressureDN8 - DN65 (1/4* to $2 \frac{1}{2}^{*}$): 27.5 bar g; L-type DN80 (3”): 27.5 bar g; H-type DN80 (3”): 20.6 bar g; DN100 - DN200: 18.3 bar g

Materials

No.ComponentMaterial
1Housing bottom coverStainless steel (CSF16: 1.4301; CSF16T: 1.4404)
2Housing top coverStainless steel (CSF16: 1.4301; CSF16T: 1.4404)
3Housing sealDN8 - DN80: EPM; DN100 - DN200: stainless steel spiral-wound PTFE seal
4Housing ring (DN8 - DN80)Stainless steel 1.4301
5CSF16 - A filter elementFilter element material: borosilicate; housing: 1.4301
6Filter element seal (2 off)Silicone VMQ
7PlugStainless steel (CSF16: 1.4301; CSF16T: 1.4404)
8GasketPTFE
9FlangeStainless steel 1.4541
10Bolts and nuts (DN100 - DN200)Stainless steel A2 - 70

Gas Pressure Capacity Correction Factors

Compressed air pressure (bar g)12345678910111213141516
Correction factor0.250.3750.50.6250.750.8751.01.1251.251.3751.51.6251.751.8752.02.125

Selection Table

The flow rates below are calculated based on compressed air at 7barg.

SizeDN8DN10DN15DN20DN25DN32DN40DN50LDN50HDN65DN80LDN80HDN100LDN100HDN150LDN150HDN200LDN200H
Corresponding size1/4”3/81/2”3/41”11/4”11/2”2”L2”H21/23”L3”H4”L4”H6”L6”H8’‘L8”H
Maximum flow rate ($m^{3}/h$)60901201802703604807201080144019202880432057607680115201536019200

Safety Information, Installation and Maintenance

For details, refer to the installation and maintenance instructions IM - P185 - 02 supplied with the product.

Ordering

The following information must be specified when ordering Spirax Sarco filters:

ItemDetails
Compressed air flow rate$m^{3}/h$
Compressed air pressurebar
Allowable pressure drop(0.07bar maximum recommended)
Housing material1.4301 or 1.4404
SizeDN or NPS(”)
Pipe connectionEN, ASME, BSP or NPT
Housing seal/filter element seal material

Note: For DN50 and DN80, high-flow versions are designated “H” and low-flow versions “L”. For 1.4404 housings, the suffix “T” must be added, as in CSF16T.

Supply

CSF16 is supplied in two parts:

  • Housing bottom cover, top cover and housing seal.

  • 2 sets of CSF16 - A borosilicate filter elements.

Note: The filter element removes contaminants from the medium and becomes saturated after a period of service. To minimize downtime, ordering an additional filter element and housing as spare parts is recommended.

For spare part orders, order the required parts as described in the table above and specify the filter housing model and size. Example: one seal set for a Spirax Sarco DN200H CSF16 filter.