Description
Spirax Sarco EL2600 pressure transmitter consists of a pressure sensor and transmitter designed for industrial applications. It uses a 2-wire 4 - 20mA current loop and a ¼” NPT connection. Two “U” tube and valve options are available, with maximum design pressures of 25bar g and 80 bar g, respectively.
Pressure Ranges and Overload Pressure
Different pressure ranges correspond to different overload pressures. For example, the overload pressure for the 0 - 1.6 bar a and 0 - 2.5 bar a ranges is 10bar. Exceeding the overload pressure can damage the sensor, even for a short period. If excessive pressure may occur, use a pressure snubber or select a pressure transmitter with a higher range, although this may reduce signal resolution.
Connection Method
When the fluid temperature is below 100°C, EL2600 can be installed directly on the pipe through the ¼” NPT connection. When the temperature exceeds 100°C, a “U” tube and isolation valve must be installed between EL2600 and the pipe or vessel.
Technical Data
| Parameter | Details |
|---|---|
| Sensor type | Piezoresistive sensor for 0 - 1.6 bar a to 0 - 16 bar g; diaphragm sensor for 0 - 25 bar g to 0 - 400 bar g |
| Voltage | 10 Vdc to 30 Vdc |
| Accuracy | ≤0.5% |
| Repeatability | ≤0.05 of span |
| Hysteresis | ≤0.1% of span |
| Protection rating | IP65 |
Certifications
| Certification | Details |
|---|---|
| EMC emissions | BS EN 61326: 1997 A1 and A2 Table 4 |
| EMC immunity | BS EN 61326: 1997 A1 and A2 Table 4 ANNEX A |
Materials
EL2600 body: stainless steel 316L WS 1.4435. Connection material: polyamide PA 66. Low-pressure “U” tube: stainless steel. Low-pressure isolation valve body: stainless steel. High-pressure “U” tube: BS3602:Part.1 1987 CFS 360, zinc passivated. High-pressure isolation valve body: PEEK/Polymain.
Installation and Maintenance
A “U” tube and isolation valve must be used when the temperature exceeds 100°C. No special maintenance is required, but annual inspection and testing are recommended. For further information, refer to Installation and Maintenance Instructions IM - GCM - 10.
Weight
EL2600 weight is 0.2kg. “U” tube and valve weight is 0.5kg.
Ordering Information
Example: 1 - Spirax Sarco EL2600 pressure transmitter, pressure range 0 - 16bar g, with “U” tube and isolation valve.