Description

Spirax Sarco EL2600 pressure transmitter consists of a pressure sensor and transmitter designed for industrial applications. It uses a 2-wire 4 - 20mA current loop and a ¼” NPT connection. Two “U” tube and valve options are available, with maximum design pressures of 25bar g and 80 bar g, respectively.

Pressure Ranges and Overload Pressure

Different pressure ranges correspond to different overload pressures. For example, the overload pressure for the 0 - 1.6 bar a and 0 - 2.5 bar a ranges is 10bar. Exceeding the overload pressure can damage the sensor, even for a short period. If excessive pressure may occur, use a pressure snubber or select a pressure transmitter with a higher range, although this may reduce signal resolution.

Connection Method

When the fluid temperature is below 100°C, EL2600 can be installed directly on the pipe through the ¼” NPT connection. When the temperature exceeds 100°C, a “U” tube and isolation valve must be installed between EL2600 and the pipe or vessel.

Technical Data

ParameterDetails
Sensor typePiezoresistive sensor for 0 - 1.6 bar a to 0 - 16 bar g; diaphragm sensor for 0 - 25 bar g to 0 - 400 bar g
Voltage10 Vdc to 30 Vdc
Accuracy≤0.5%
Repeatability≤0.05 of span
Hysteresis≤0.1% of span
Protection ratingIP65

Certifications

CertificationDetails
EMC emissionsBS EN 61326: 1997 A1 and A2 Table 4
EMC immunityBS EN 61326: 1997 A1 and A2 Table 4 ANNEX A

Materials

EL2600 body: stainless steel 316L WS 1.4435. Connection material: polyamide PA 66. Low-pressure “U” tube: stainless steel. Low-pressure isolation valve body: stainless steel. High-pressure “U” tube: BS3602:Part.1 1987 CFS 360, zinc passivated. High-pressure isolation valve body: PEEK/Polymain.

Installation and Maintenance

A “U” tube and isolation valve must be used when the temperature exceeds 100°C. No special maintenance is required, but annual inspection and testing are recommended. For further information, refer to Installation and Maintenance Instructions IM - GCM - 10.

Weight

EL2600 weight is 0.2kg. “U” tube and valve weight is 0.5kg.

Ordering Information

Example: 1 - Spirax Sarco EL2600 pressure transmitter, pressure range 0 - 16bar g, with “U” tube and isolation valve.