Description
Spirax Sarco BT6-B clean service balanced pressure steam traps are designed for condensate removal in clean and pure systems, including sterilizers, main drainage, CIP/SIP systems, and process piping. The valve body is manufactured from 316L stainless steel, and the seat is inclined at 15° to ensure self-drainage. The temperature-sensitive element responds precisely to condensate temperature and discharges at a temperature close to saturation temperature. In typical clean applications with steam pressure below 2.5barg, the drainage temperature is within 2℃ of saturated steam temperature. Each steam trap is individually packaged in a clean environment, with protective caps fitted to the inlet and outlet and sealed in a plastic bag.
Sizes and Piping Connections
Available in 1/2”, 3/4”, 1”, and 1 1/2” sizes, with ASME BPE sanitary clamp connections. Contact Spirax Sarco for other connection options.
Materials
| No. | Component | Material | Standard |
|---|---|---|---|
| 1 | Upper valve body | Stainless steel | ASTM A276 316L |
| 2 | Lower valve body | Stainless steel | ASTM A276 316L |
| 3 | Temperature-sensing element | Stainless steel | AISI 316L |
| 4 | Valve body connecting clamp housing | Stainless steel | AISI 316 |
| 5 | Seal ring | Tuf-steel PTFE + AISI 316; Viton seal rings with PTFE jackets are available for the dairy industry |
Available Models
| Model | Capacity characteristic |
|---|---|
| BT6-BL | Low capacity |
| BT6-BH | High capacity |
Pressure/Temperature Limits (ISO 6552)
| Valve body design condition | Parameter |
|---|---|
| PN | 10 |
| PMA maximum allowable pressure | 10 bar g 140°C |
| TMA maximum allowable temperature | 177°C@9.2barg |
| Minimum allowable temperature | -254°C |
| PMO maximum operating pressure with saturated steam | 6 bar g |
| TMO maximum operating temperature | 165°C@6 bar g |
| Minimum operating temperature | 0°C |
| Maximum cold hydraulic test pressure | 15 bar g |
Note: Refer to im-P180-31issue9 for information on conducting hydraulic tests.
Surface Finish
The internal surface is polished to 0.6μm(25 micro-inch Ra), and the external surface is polished to 1.0μm(40 micro-inch Ra). Electropolishing to 0.375μm(15 micro-inch Ra) is available as an option.
Other Options
For applications requiring a discharge temperature close to saturated steam temperature, such as critical SIP applications, contact Spirax Sarco.
Standards
The product fully complies with ASME BPE and the European Pressure Equipment Directive 2014/68/EU. All seals comply with FDA CFR title 21,part 177,section 1550 and USP24 Class VI, and are ADI (animal-derived ingredient)-free.
Note: For sanitary clamp connections, the maximum pressure/temperature may be determined by the gasket or clamp. Contact Spirax Sarco for detailed information.
Certificates
EN 10204 3.1 material certificates, internal surface finish certificates, and FDA/USP certificates are available at an additional cost.
Capacity (in accordance with ISO 7842)
Different models provide different cold-water and hot-water capacities at different differential pressures.
Safety Information, Installation, and Maintenance
For detailed information, refer to the installation and maintenance guide (IM-P180-31) supplied with the product.
Installation Notes
BT6-B is designed for vertical installation with the flow direction downward to ensure self-drainage of the valve body. During installation, check the flow-direction arrow on the valve body. Gaskets and installation clamps are not supplied with the product. A cooling section of pipe must be provided upstream to prevent condensate from accumulating in the process equipment during normal operation. The temperature-sensing element must not be exposed to superheated conditions. Handle all components carefully to prevent damage to machined surfaces.
Operation
The operating element is a stainless steel capsule filled with temperature-sensitive fluid. During cold start-up or under cold conditions, the capsule is relaxed and the valve plug and seat are fully open, allowing large quantities of air, condensate, and IP medium to be discharged. As the system temperature approaches saturated steam temperature, the fluid inside the capsule expands and closes the valve to prevent steam leakage. The closing temperature is close to saturated steam temperature, ensuring effective system drainage.
Ordering
Example: 1 Spirax Sarco BT6-BH clean service balanced pressure steam trap, with ASME BPE sanitary clamp connections, maximum operating pressure 6bar g, internal surface electropolished to 0.375μm(15 micro-inch Ra), with an EN102043.1 material certificate.
Weight
| Size | Weight(kg) |
|---|---|
| 1/2” | 0.70 |
| 3/4” | 0.71 |
| 1” | 0.94 |
| 1 1/2” | 0.86 |