Description

Spirax Sarco BT1050 boiler blowdown controller is a timer for controlling the bottom blowdown valve. It allows the bottom blowdown valve to open and remove settled solids, which could otherwise accumulate and eventually damage the boiler. BT1050 has three timers that can be configured with different cycle intervals and durations. For example, up to 3 blowdown cycles per day can be selected from Monday through Friday. The timer can also set the priority sequence for boiler blowdown.

The product is available for panel, DIN rail, or baseplate mounting and is powered by a 99 to 264 Vac supply. The front panel includes an LCD display and a five-button keypad. A test function provides a diagnostic tool for users. BT1050 can communicate with adjacent devices via infrared. It can be configured as a slave or master and connected to a two-wire or four-wire EIA/TIA-485 multidrop network. Up to 9 BT1050 (or BT1000) units can be installed and used for multiple-boiler blowdown applications.

Certifications

BT1050 complies with the EMC Directive 2014/30/EU and its requirements. This product is suitable for Class A environments, such as industrial environments. The product has a detailed EMC assessment, reference UK Supply BH BT1050 2008.

BT1050 complies with the Low Voltage Directive (2014/35/EU) and meets the requirements of:

  • EN 61010-1:2001, safety requirements for electrical equipment for measurement, control, and laboratory use.

BT1050 is UL listed (open).

Key Features

  • Specifically designed for bottom blowdown.

  • Three independently adjustable timers.

  • Simple commissioning with fast setup options.

  • Wide power supply range: 110-240Vac.

  • Timer prevents continuous rapid boiler blowdown.

  • Alarm indication if the valve fails to open or close.

  • UL and TÜV certified.

Technical Specifications

ParameterDetails
Supply voltage110 - 240Vac, 50/60HZ
Power consumption7.5W (maximum)
Application environmentIndoor use only
Maximum altitude2000 m above sea level
Ambient temperature range0 - 55 °C
Maximum relative humidity80% up to 31 °C decreasing linearly to 50% at 40 °C
Overvoltage categoryIII
Enclosure rating (front panel only)NEMA 4 hose-tight (UL certified) and IP65 (TRAC Global certified)
LVD (safety)Electrical safety EN 61010-1 UL61010-1, 3rd Edition, 2012-05
EMCCAN/CSA-C22.2 No. 61010-1, 3rd Edition, 2012-05; immunity for industrial locations: EN 61326: A1 + A2 Annex A Table 1; emissions: EN 61326: A1 + A2 Class A Table 4
Enclosure materialPolycarbonate
Front panel materialSilicone rubber, 60 shore
SolderTin/lead (60/40%)
Power and signal connectorsPluggable terminal blocks with screw connectors. Note: use only terminals supplied by Spirax Sarco; otherwise, safety and approvals may be compromised.
Cable size0.2 mm² (24 AWG) - 2.5 mm² (12 AWG)
Strip length5 - 6 mm
Cable/wire and connector data (connecting) circuitCores: 2; size: 1 – 1.5 mm² (18 - 16 AWG); maximum length: 100 m; recommended types: Prysmian (Pirelli) FP200, Delta Crompton Firetuf OHLS
RS485 communication cable/wiringType: EIA RS485 twisted pair; shielding: screened; LAN Cat 5 or Cat 5E ScTP (screened), FTP (foil), or STP Alpha 6413 or 6414 may be used, limited to 600 m; pairs: 2 or 3; size: 0.23 mm² (24 AWG); maximum length: 1200 m (4000 ft); recommended types: Alpha 6413 or 6414
Input - switch boxMaximum voltage: 32Vdc (no load, open circuit); maximum current: 3mAdc (short circuit)
Input - interlock (connecting)Maximum voltage: 32Vdc (no load, open circuit); maximum pull-down voltage: 0.25 Vdc; maximum current: 1.5 mAdc
RS485Physical layer: RS485 4-wire full duplex or 2-wire half duplex; protocol layer: Modbus RTU format; isolation: 60 Vac/dc; output rate: up to 10 frames/s
Battery (real-time clock)Type: AA (PCB) lithium thionyl chloride (lithium content 0.65 g); shelf life: 10 years battery-powered @ Tamb: 25 °C; operating life: 10 years powered 35 hours/week @ Tamb: 55 °C
InfraredPhysical layer: IrDA; baud rate: 38400; range: 10 cm; operating angle: 15 °; eye safety information: summary: EN 60825-12 : 2007 - laser product safety, not exceeding Class 1 accessible emission limits (AEL)
RelaysContacts: 2 x single-pole changeover relays (SPCO); rated voltage (maximum): 250 Vac; load - resistive: 3 amp @ 250 Vac; load - inductive: 1 amp @ 250 Vac; load - AC motor: ¼ HP (2.9 amp) @ 250 Vac, 1 / 10 HP (3 amp) @ 120 Vac; pilot duty: C300 (2.5 amp) - control circuit / coil; electrical life (operations): 3 x 10 5 or greater, depending on load; mechanical life (operations): 30 x 10 6

Weight

Approximate weight: 400g

Safety Information, Installation, and Maintenance

This document does not contain sufficient information for safely installing the product. Refer to the installation and maintenance guide supplied with the product for detailed wiring, commissioning, and operating instructions. Refer to safety information sheet IM-GCM- 10 and any national regulations concerning blowdown. In the UK, refer to Health and Safety Guidance Note PM60. Pay particular attention to the hazards associated with working on one boiler while other boilers remain in operation.

  • Warning:

Disconnect the power supply before installing the controller because the power supply terminals are exposed.

  • Use only the screws supplied with the product.

  • Do not install outdoors without additional weather protection.

  • Do not drill holes in the product or use self-tapping screws.

  • Caution: A 15 mm clearance is required between multiple controllers for cooling.

  • Installation/environmental conditions: Install the product in an environment that minimizes exposure to heat, vibration, shock, and electrical interference. The product must be installed inside a suitable industrial control panel or fireproof enclosure to provide protection against impact and environmental conditions. The minimum requirement is IP54 (EN 60529) or Type 3, 3S, 4, 4X, 6, 6P, and 13 (UL50/NEMA 250). The product can be DIN rail, baseplate, or panel mounted. A panel bezel is provided.

Product Description

Blowdown timer with three integrated timers, LCD display, valve fault alarm, and infrared communication.

How to Order

Example: 1 Spirax Sarco BT1050 blowdown timer