Description

Spirax Sarco M70i ISO stainless steel hygienic ball valve for clean service systems is a three-piece ball valve forged from 316L stainless steel and designed for ISO installation standards. The design complies with ASME BPE standards for steam and other high-purity systems, as well as aseptic processes where bacteria and media residue could affect product quality. This valve is intended for isolation service and must not be used for throttling control. Its low-maintenance, hygienic design is suitable for steam, liquid and gas systems, covering applications from vacuum service to high-temperature, high-pressure systems in the pharmaceutical, bioprocessing, food, beverage and cosmetic industries.

Key Features

  • Full-bore design: the inside diameter of the connection ports matches the inside diameter of the ball for excellent draining performance.

  • Forged construction, manufactured from high-quality forged stainless steel ASTM A182 F316L.

  • Low ferrite content: ferrite content in the body and connection ports is only 3%-5%, helping prevent oxidation.

  • Designed for automatic welding. The ASME BPE-compliant design meets automatic welding requirements, allowing welding to be performed on the extended tube ends without disassembling the valve.

  • Automation-ready design with an ISO 5211 mounting pad for easy actuator installation.

  • Lockable handle. The spring-loaded locking handle allows the valve to be locked in the selected position to help ensure system safety.

Surface Finish

The standard valve has an internal surface finish of 0.5 micrometers Ra (20 microinches). An electropolished internal surface finish of 0.375 micrometers Ra (15 microinches) is available as an option. The external surface has a natural forged/machined finish.

Available Models

M70iV ISOVirgin PTFE TFM 1600
M70iVEP ISOVirgin PTFE TFM 1600 electropolished to 0.375 micrometers R
M70iG ISOMineral-filled PTFE
M70iGEP ISOMineral-filled PTFE electropolished to 0.375 micrometers R

Other Options

  • An optional 100mm (4”) extended stem allows the valve to be insulated.

  • Cavity filler is supplied as standard. If cavity filler is not required, specify this when ordering. Low oxygen content <1%.

Standards

This product complies with the European Pressure Equipment Directive 97/23/EC.

Certificates

  • Material certificate EN 10204 3.1.

  • FDA/USP certificate for elastomeric components.

  • Surface finish certificate.

Note: Specify any required certificates or inspections when ordering.

Packaging

M70i is processed and packaged in a clean environment. In accordance with ASME BPE standards, both ends of each valve are sealed with caps, and the complete valve is sealed in a plastic bag to prevent dust ingress.

Sizes and Pipe Connections

½”, ¾”, 1”, 1½”, 2” sanitary clamp connections (ASME BPE).

½”, ¾”, 1”, 1½”, 2” extended O/D butt-weld tube ends (ETO) (ASME BPE).

Sanitary clamp/ETO combination connections.

2½”, 3” and 4” forged ball valves are available on special request.

Option: For 2½”, 3” and 4” investment-cast hygienic ball valves, refer to the M80i technical documentation.

Note: Contact Spirax Sarco for other connection options.

Pressure/Temperature Limits

Valve body design conditionsPN63
PMA maximum allowable pressure62 bar g@20 ℃
TMA maximum allowable temperature200 ℃ @0 bar g
Minimum allowable temperature-29 ℃
PMO saturated steam pressureVirgin PTFE7.0 bar g
Maximum operating pressureMineral-filled PTFE8.5 bar g
TMO maximum operating temperature200 ℃ @0 bar g
Minimum operating temperature-29 ℃
Note: Contact Spirax Sarco for lower operating temperatures
D PMX maximum differential operating pressure determined by PMO
Maximum design cold hydraulic test pressure93 bar g

Materials

No.ComponentMaterial
1BodyStainless steel ASTM A 182 F316L
2Connection endStainless steel ASTM A 182 F316L
3BallStainless steel AISI 316L
4StemStainless steel AISI 316L
5SeatM70i G: mineral-filled PTFE
M70i V: virgin PTFE TFM 1600
6Stem sealVirgin PTFE TFM 1600
7GasketStainless steel AISI 316
8Compression nutStainless steel AISI 316
9Locking washerStainless steel AISI 316
10Stem nutStainless steel AISI 316
11Nameplate (not shown)Stainless steel AISI 430
12HandleStainless steel AISI 316
13Handle sleeveEthylene resin
14Bolts and nutsStainless steel AISI 316
15Cavity fillerVirgin PTFE TFM 1600
16Cap gasketVirgin PTFE TFM 1600
17Belleville washerStainless steel AISI 316
18Stem sealINOX

Technical Data

Leakage rateTest procedure complies with ISO 5208 (Class A)/EN12266-1 (Class A)
Stem seal and seat- FDA CFR title21 paragraph177 section 1550 - USP 23 Class VI
Flow characteristicModified linear
Flow passageFull bore

The torque values above apply to valves operated frequently at maximum operating pressure. Torque may increase for valves that remain stationary for extended periods.

Weight

Size (clamp/ETO)Weight (kg)
½”0.80
¾”1.00
1”1.55
1½”4.50
2”7.70

Safety Information, Installation and Maintenance

Refer to the installation and maintenance guide supplied with the product.

Ordering

When ordering an M70i stainless steel hygienic ball valve, specify the following details: size, connection type, seat material, internal surface finish and required certificates. Note: Cavity filler is supplied as standard. If it is not required, specify this when ordering.

Example: 1 - Spirax Sarco ½” M70iV ISO forged stainless steel hygienic ball valve with clamp connection (ASME BPE), internal surface finish of 0.5 micrometers Ra (20 microinches), supplied with EN10204 3.1 certificate.