Description

DCV10 (stainless steel) and DCV10C (carbon steel) wafer check valves are designed for installation between flanges, specifically for water pumps and other circulating applications. They are suitable for a wide range of process media, process pipelines, hot water systems, steam systems, and condensate systems. Compared with conventional wafer check valves, the center guide design provides longer and more reliable service life. The check valve maintains the correct flow direction of condensate or other suitable fluids while preventing reverse flow.

Standard: Design complies with BS EN 14341: 2006. This product is fully compliant with the European Pressure Equipment Directive 97/23/EC and can be supplied with CE marking when required. Disc-to-seat sealing complies with EN 12266-1: 2003 Grade F.

Certificates: An EN10204 3.1 material certificate is available. Note: Please specify when ordering if a material certificate or inspection certificate is required.

Size and Pipe Connections

Sizes: DN25, DN40, DN50, DN80, DN100, DN125, DN150, DN200 and DN250

For DN25-DN100, the PN rating is suitable for the following flanges: EN1092 PN25, PN16, PN40, JIS / KS 10K and JIS / KS 20K.

For DN125-DN250, ASME (ANSI) 300 rating is suitable for the following flanges: EN 1092 PN25, PN16, PN40 and JIS / KS 20K; (ANSI) B 16.5 Class 150 and Class 300. EN 558 Series 49 (DN125-DN200) and EN558 Series 52 (DN250).

Materials

DCV10 and DCV10C (DN25-DN100)

No.ComponentMaterial
1BodyPN: Austenitic stainless steel 1.4308; ASME: Austenitic stainless steel A351 CF8
2DiscDN25-DN40: Austenitic stainless steel A276 316L; DN50-DN100: Austenitic stainless steel AISI 316L
3RetainerMartensitic BS 3146-2 ANC2
4SpringStainless steel BS2056 316 S42
5GasketFiller-reinforced graphite

DCV10 and DCV10C (DN125-DN250)

No.ComponentMaterial
1BodyDCV10 PN: Austenitic stainless steel 1.4308; ASME: Austenitic stainless steel 351 CF8
DCV10C PN: Carbon steel 1.0619+N; ASME: Carbon steel A216 WCB
2DiscPN: Austenitic stainless steel 1.4308; ASME: Austenitic stainless steel A351 CF8
3SeatPN: Austenitic stainless steel 1.4308; ASME: Austenitic stainless steel A351 CF8
4SpringStainless steel 316L
5GasketFiller-reinforced graphite

Kv Values

DNDN25DN40DN50DN80DN100DN125DN150DN200DN250
KV10.8264380130188213432735

Pressure/Temperature Limits

DCV10 (DN25 - DN100)

ParameterDN25 - DN80DN100
Body design ratingPN25, PN16 or ASME (ANSI) Class 300Same as left
PMA body design rating (max. allowable pressure)PN25: 25 bar g @ 0 °C
PN40: 40 bar g @ 0°C
ASME Class 300: 49.6 bar g @ 0 °C
Same as left
TMA maximum allowable temperaturePN25: 200°C @ 17.2 bar g
ASME Class 300: 200°C @ 34.5 bar g
PN25: 200°C @ 17.2 bar g
ASME Class 300 (DN100): 400°C @ 28.4 bar g
Minimum allowable temperature-10°C-10°C
PMO maximum operating pressurePN25: 25 bar g @ 0 °C
ASME Class 300: 49.5 bar g @ 0 °C
Same as left
TMO maximum operating temperaturePN25: 200°C @ 17.2 bar g
ASME Class 300: 200°C @ 34.5 bar g
PN25: 200°C @ 17.2 bar g
ASME Class 300 (DN100): 400°C @ 28.4 bar g
Temperature limits-10°C to +200°C-10°C to +400°C

Maximum design cold hydraulic test pressure: PN25: 37.5 bar g; ASME Class 300 DN25 - DN100: 74.4 bar g

DCV10 (DN125-DN250) & DCV10C (DN125-DN250)

ParameterDCV10DCV10C
Body design ratingPN40 or ASME (ANSI) Class 300PN40 or ASME (ANSI) Class 300
PMA maximum allowable pressure49.6 bar g @ 38°C51.1 bar g @ 38°C
TMA maximum allowable temperature400°C @ 28.4 bar g400°C @ 34.7 bar g
Minimum allowable temperature-29°C-29°C
PMO maximum operating pressure33 bar g @ 241°C42 bar g @ 255°C
TMO maximum operating temperature400°C @ 28.4 bar g400°C @ 34.7 bar g
Temperature limits-29°C to +400°C-29°C to +400°C

Maximum design cold hydraulic test pressure: 77 bar g

Operating Principle

DCV10 and DCV10C open when fluid pressure acts in the forward flow direction. Spring force closes the disc before reverse flow occurs.

Weight

DN25 - DN100

DNWeight
DN250.40
DN400.82
DN501.34
DN802.56
DN1005.30

DN125 - DN250

DNWeight
DN12511.00
DN15016.00
DN20032.00
DN25060.00

Installation Notes

Install DCV10 and DCV10C horizontally or vertically according to the flow direction marked on the valve body. Note: Flanges, bolts (or studs), nuts, and gaskets are to be supplied by the user.

Disposal Information

These products are recyclable. When disposing of the products, handle them carefully to prevent environmental pollution or hazards.

How to Order

Example: 1 Spirax Sarco DN80 DCV10 stainless steel check valve, installed between PN16 flanges.

Spare Parts

DCV10 and DCV10C require no maintenance and have no spare parts.

WeChat ID copied