Description

Spirax Sarco LP10-4 level sensor is used with Spirax Sarco LC1350 level controller for on/off level control and alarm functions in steam boilers, water tanks, or other vessels. The 4-probe sensor is suitable for applications with a 3-lamp electronic level/alarm display. Sensor body grounding is provided through the threaded connection. When installed in concrete or plastic tanks, one probe can be used for grounding, or a separate grounding rod or plate can be provided. The 4 probes are removable and can be cut to the required length before installation (probes must be ordered separately). When immersed in a conductive liquid, the probes complete an electrical circuit; as the liquid level falls below a probe, resistance increases and a signal is sent to the controller.

Probe Length

Probe length is 1000 mm, with a maximum length of 2095 mm when two probes are connected.

Pressure/Temperature Limits

Pressure ratingPN40
Maximum pressure32 bar g (464 psi g)
Maximum temperature239 °C (462 °F)
Maximum ambient temperature70 °C (158 °F)
Minimum ambient temperature-20 °C (-4 °F)

Technical Data

Protection ratingIP54
Maximum cable length (sensor to controller)30 m (98 ft)
Maximum sensing temperature2095 mm (82.5”)
Minimum sensing depth75 mm (3”)
Minimum conductivity (when used with LC1350)1S/cm @ 25℃

Materials

No.ComponentMaterial
1Protection bodyAustenitic stainless steel BS EN 10088-3 (1.4306)
2ProbeAustenitic stainless steel Type 316/ 316L
3Probe insulation sleevePFA (Per Fluor Alkoxy)
4Lower wire coverPPS (Polyphenyline sulphide)
5Upper wire coverPPS (Polyphenyline sulphide)
6Cable gland support padElastic thermoplastic
7Cable glandPolyamide
8Probe statorPEEK (Polyaryletherketone) Grade 450G

Safety, Installation and Maintenance

This document does not contain sufficient safety and installation information. Refer to the installation and maintenance instructions supplied with the product.

Warning: If this product is exposed to excessive heat, the plastic materials it contains may release toxic fumes.

Installation: LP10-4 is designed for installation in a BSPRP1 (1” BSP tapered) or 1” NPT threaded flange or cover. The thread specification must be stated when ordering. When installed in boilers or water tanks subject to severe turbulence, a protection tube with a minimum nominal bore of 80 mm is recommended. Outdoor installations must be protected from weather exposure.

Wiring: Wiring LP10-4 is simple and direct. Wiring connectors are available as spare parts, and the terminals are color-coded for identification. To disconnect the wiring, open the wire assembly; it is not necessary to remove the cable gland.

Maintenance: Although boiler water level controls require periodic testing, this product requires no special maintenance.

Product Description

Austenitic stainless steel body and sensor probes with PFA probe insulation, for boilers with a maximum pressure of 32 bar g (239 °C).

Ordering Information

Example: 1 - Spirax Sarco LP10-4 sensor (BSP), probe length 1000 mm.

Available Spares

LP10-4 wiring connector: Includes 6 flat connectors and 2 round connectors.

LP10-4 probe mounting kit: Includes 1 single-probe connector, 1 locking screw nut, and 2 probe stators.

Weight

1.15kg