Description

Spirax Sarco TDS46M stainless steel thermodynamic steam trap with a replaceable seat, specifically designed for low-capacity applications and rated for a maximum operating pressure of 46 bar g. Threaded, socket-weld, or integral flanged connections are available.

This steam trap features an integral strainer, integral air vent, insulation cover, and replaceable seat. An optional BDV1 integrated blowdown valve can be installed on the strainer cover; specify this option when ordering.

Standards and Certificates

This product complies with the European Pressure Equipment Directive 97/23/EC and is available with an EN 10204 3.1 certificate. Note: Specify the certificate requirement when ordering.

Sizes and Pipe Connections

  • ½”, ¾” and 1” threaded connections, BSP or NPT

  • ½”, ¾” and 1” socket-weld connections, BS 3799 Class 3000 lb

  • DN15, DN20 and DN25 integral flanges, EN 1092 PN40, PN100, ASME Class 150, ASME Class 300, or ASME Class 600

Materials

ItemMaterial
1Body: stainless steel 1.4308 / ASTM A351 CF8
2Cover: stainless steel 1.4301 / ASTM A479 304
3Insulation cover: stainless steel EN 10088-1 1.4301
4Disc: hardened steel 1.2379
5Seat: hardened steel 1.2379
6Bimetallic ring: bimetal
7Support ring: stainless steel AISI 304
8Seat gasket: reinforced exfoliated graphite
9Strainer: stainless steel ASTM A478 316L
10Strainer cover gasket: stainless steel AISI 304
11Strainer cover: stainless steel 1.4308 / ASTM A351 CF8

Pressure/Temperature Limits (ISO 6552) - Threaded, Socket-Weld and EN 1092 Flanged Connections

ClassificationParameterDetails
PN100Body design pressurePN100
PMA maximum allowable pressure100 bar g @ 50°C
TMA maximum allowable temperature450°C @ 58.3 bar g
Minimum allowable temperature-50°C
PMO maximum operating pressure46 bar g @ 450°C
TMO maximum operating temperature450°C @ 46 bar g
Minimum operating pressure0°C
Minimum operating temperature1.5 bar g
Maximum operating backpressureNot exceeding 80% of upstream pressure
Maximum designed cold hydraulic test pressure150 bar g
PN40Body design pressurePN40
PMA maximum allowable pressure40 bar g @ 50°C
TMA maximum allowable temperature450°C @ 23.3 bar g
Minimum allowable temperature-50°C
PMO maximum operating pressure28.4 bar g @ 233°C
TMO maximum operating temperature450°C @ 23.3 bar g
Minimum operating pressure0°C
Minimum operating temperature1.5 bar g
Maximum operating backpressureNot exceeding 80% of upstream pressure
Maximum designed cold hydraulic test pressure60 bar g

Pressure/Temperature Limits (ISO 6552) - ASME Flanged Connections

ClassificationParameterDetails
ASME Class 600Body design pressureASME Class 600
PMA maximum allowable pressure99.3 bar g @ 38°C
TMA maximum allowable temperature450°C @ 54.8 bar g
Minimum allowable temperature-50°C
PMO maximum operating pressure46 bar g
TMO maximum operating temperature450°C @ 46 bar g
Minimum operating pressure0°C
Minimum operating temperature1.5 bar g
Maximum designed cold hydraulic test pressure149 bar g
ASME Class 300Body design pressureASME Class 300
PMA maximum allowable pressure49.6 bar g @ 38°C
TMA maximum allowable temperature450°C @ 27.4 bar g
Minimum allowable temperature-50°C
PMO maximum operating pressure33 bar g
TMO maximum operating temperature450°C @ 27.4 bar g
Minimum operating pressure0°C
Minimum operating temperature1.5 bar g
Maximum operating backpressureNot exceeding 80% of upstream pressure
Maximum designed cold hydraulic test pressure74.4 bar g
ASME Class 150Body design pressureASME Class 150
PMA maximum allowable pressure19 bar g @ 38°C
TMA maximum allowable temperature450°C @ 4.6 bar g
Minimum allowable temperature-50°C
PMO maximum operating pressure14 bar g
TMO maximum operating temperature450°C @ 4.6 bar g
Minimum operating pressure0°C
Minimum operating temperature1.5 bar g
Maximum operating backpressureNot exceeding 80% of upstream pressure
Maximum designed cold hydraulic test pressure28.5 bar g

Weight (Approximate) kg

SizeThreadedSocket-WeldASME 150ASME 300ASME Class 600 FlangedPN40PN100
½” (DN15)1.381.492.462.963.063.064.36
¾” (DN20)1.641.643.164.064.263.966.26
1” (DN25)1.901.904.165.165.464.868.16

Installation Instructions

TDS46M is designed for horizontal installation with the insulation cover positioned at the top.

If downstream backpressure is present, installation of a check valve is recommended.

If discharging directly to atmosphere, installation of a silencer downstream is recommended.

For ease of maintenance, isolation valves should be installed upstream and downstream of the steam trap.

Ordering Information

Example: 1 - Spirax Sarco DN15 TDS46M thermodynamic steam trap with PN40 flanged connections.

Spare Parts

Solid-line items in the illustration are available as spare parts; dashed-line items are not supplied as spare parts.

  • Insulation cover

  • Cover, seat and disc assembly (2, 4, 5, 6, 7, 8)

  • Strainer and gaskets (9, 10)

  • Gasket set (3 sets) (8, 10)

  • BDV1 blowdown valve assembly

To order spare parts, order according to the descriptions above and specify the steam trap size and model.

Example: 1 - Cover, seat and disc assembly for Spirax Sarco DN15 TDS46M thermodynamic steam trap.

斯派莎克 Spirax Sarco TDS46M可更换阀座的 不锈钢热动力型蒸汽疏水阀 - 结构图

WeChat ID copied